MG MASTER HV - High Voltage BMS 144-800V/500A


Price:
Sale price$13,282.95

Description

MG MASTER HV - High Voltage BMS 144-800V/500A

MG Energy Systems Master HV Series - Next Generation LiIon Battery Solutions
800V 500A High-Voltage battery management control unit for battery systems 144V - 800V, With CAN-Bus communication Compact design
Redundant Battery Management System
Easy installation
Integrated pre-charging
Compliant with the highest safety standards
Internal event logging

Protecting, monitoring and controlling a battery system is very important to create a safe, reliable and easy-to-use system. The MG Master HV is the safety and control unit of the battery system. It protects the connected battery modules against over-charging, over-discharging, over-temperature, under-temperature and controls the balancing of the battery cells. Besides a safety function, the Master HV monitors and tracks other important parameters to give insight in the battery status and energy consumption. The compact design makes it ideal for use in applications with limited space.

Specifications:
- Communication: CAN-Bus (NMEA2000, SMA, custom on request)
- Humidity: Max. 95% (non-condensing)
- Operating temperature range: -20°C to + 50ºC
- Protection class: IP65
- Power connections: Anphenol Powerlok 500 series
- Max. HV current continuous: 500A
- M12 Connection

Click here to read more about MG Energy integration with Victron Energy products and DVCC

Power Connectors
Power connectors enable the Master HV to easily connect a series of batteries. The Amphenol PowerLok connectors are robust and have an integrated HVIL (High Voltage Interlock Loop) to monitor the connection. The low contact resistance allows for current up to 500 A continuously.

Monitoring and Control
Critical parameters are monitored by the Master LV such as cell voltages and temperatures of each connected battery module. A set of limits is determined providing boundaries. Several boundaries are set for each of the monitored parameters. First a control boundary which controls chargers or loads. Second a warning limit and third a critical fail which opens the safety contactors interrupting the power path from the batteries to loads and chargers. A well integrated system never opens its safety contactors during normal operation.

Diagnostic tool software
Battery system diagnostics are important during commissioning, system testing, service, maintenance and trouble shooting. The diagnostic tools provide all the detailed information about the battery system. Main values, like

Payment & Security

American Express Apple Pay Google Pay Mastercard Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.